Searching…
    Strona główna Firma Aktualności i wydarzenia DefiXpress Defibrillator Technical Specification
    Biblioteka produktów

    DefiXpress Defibrillator Technical Specification

    czerwiec 2026 2 min read

    Meditech Debrillator Monitor can work both in Automated External Debrillator (AED) mode and Manual mode and record parameters of ECG, HR and SpO2

    Meditech Debrillator Monitor can work both in Automated External Debrillator (AED) mode and Manual mode and record parameters of ECG, HR and SpO2. Features: ·
    Works both in automated external debrillator (AED) and Manual modes · Records ECG, HR and SpO2 · It has voice and visual prompts for charge prompt and shockable rhythm · It has a high-resolution display and a thermal printer

    Display:7 screen(17.7cm)diagonally
    Sweep speed:25mm/ sec
    Number of leads for ECG:3-lead ECG cable or 5-lead ECG cable, paddles
    Output:Dwufazowa
    Energy sequence:Monitor display indicates both selected and delivered energy
    Czas ładowania:<7sec with a new fully charged battery
    Charge prompts:Komunikaty głosowe i wizualne
    Zakres pomiaru impedancji elektrod:0-250Ω
    Lead selection:Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V
    ECG size:0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor
    Tętno:20-300bpm
    Heart rate alarm:On/Off displayed on monitor, user-selectable
    Smart alarm:Beeper/voice prompts indicate shockable rhythm
    SpO2 measurement range:30~100%, ±2% between 80%~90%, others ±5%
    Alarm range for SpO2 measurement range:User set high limit and low limit
    Alarm accuracy for SpO2 measurement range:±10% within setting values
    Alarm time accuracy for SpO2 measurement range:Less than 12secs
    Functions of AED mode:Auto analyse and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts
    Shockable rhythms of AED mode:Ventricular fibrillation with amplitude >=200uV ventricular tachycardia with rates >=140bpm QRS complex wave duration >=140ms
    Charge control of AED mode:Control on device front panel, press key on paddle
    Prompts of AED mode:Komunikaty głosowe i wizualne
    Energy selection of Manual mode:Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules
    Synchronization of Manual mode:Synchronizes defibrillator pulse to patient’s R-wave. ”SYNC” message displayed on monitor
    Printer paper:Papier termiczny 50mm
    Paper speed:12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay
    Printing method:High-resolution, thermal print head
    Print-out modes:Manual or automatic, user-configurable
    On/Off control:Front panel and paddle
    Automatic function:9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge
    Battery:Rechargeable, Ni-MH battery, 12V
    Battery life:For a new, fully charged battery- 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions
    Share:

    Więcej z Aktualności i wydarzeń

    Zobacz wszystkie artykuły
    Biblioteka Meditech
    Biblioteka Meditech sie 2026

    Tabela porównawcza monitora płodu-matki MD901F i MD901F-Android

      Parameter MD901F MD901F-Android Typ 12,1 cala 12,1 cala Standard Configuration FHR, TOCO, FM FHR, TOCO, FM, ekran dotykowy, sieć…

    Czytaj więcej 2 min
    Biblioteka produktów
    Biblioteka produktów cze 2026

    iBreathe TOUCH SCREEN SPIROMETER med inbyggd skrivare